Products

Greitzer Corporation, Inc
Conveyors Power Paks Ventilators


Utility Pedestal Type Power-Pak

Features:

  • Attractive and sanitary design for supplying utilities to isolated pieces of equipment.
  • Convenient electrical and mechanical utility source for mixers and cutter mixers.
  • Overall saving in cost.
  • Quality control source means fewer problems at the jobsite.
  • UL and CSA listed.
  • Individually tested to assure trouble free product.
  • Less downtime when changing individual pieces of equipment.
  • Allows for easier and faster cleaning of equipment.
  • Convenient location for motor controls, timers, duplex convenience outlets, water meters, etc.
  • Complete safety assured while working on equipment.

Some of the advantages of using Greitzer Power-Pak Utility Pedestal rather than the obsolete system of individual electric and mechanical stubs are as follows:

  1. Power-Pak Utility Pedestals are pre-wired and pre-plumbed to one connection point for electric, hot water, cold water and drain. Theelimination of the need to make individual stub-ups in the field and of making individual connections to each piece of equipment actually exceeds the cost of the Utility Pedestal and effects an overall savings in the total project cost.
  2. Greitzer Utility Pedestals are made in the controlled environment of a factory under the constant supervision of our inspectors, management and quality control. This assures the customer of fewer problems arising in the field from careless and faulty work by jobsite mechanical trades.
  3. Each Utility Pedestal is Underwriters Laboratories listed as having met or exceeded the standards of that organization. (All Utility Pedestals sold in Canada are C.S.A. listed). This assures the customer that he is purchasing the best product money can buy.
  4. Each Utility Pedestal electrical and mechanical component is individually tested before leaving our factory to assure the customer he will be receiving a trouble free product.
  5. Power-Pak Utility Pedestal construction enables you to change equipment in minutes.
  6. Attractive and sanitary design is provided for supplying electrical power, mechanical utilities, drain, motor controls, timers, electrical and electronic controls, sink with faucet and flexible hose, booster water heater and duplex convenience outlets in the middle of an open area to service isolated pieces of equipment.
  7. With permanent stub construction it is virtually impossible to clean under equipment and around stubs. Utility Pedestal construction utilizes proximity breakers with all receptacles. This allows the operator to turn off a breaker so the receptacle andplug can be separated without any fear of arcing. This means that when using a Utility Pedestal system you may put equipment on casters and allow easy movement for cleaning. The quick disconnect feature of Utility Pedestal also permits easy maintenance and repair of machinery by simplifying removal and replacement.
  8. With a Utility Pedestal system the repair mechanic can be assured he is working in complete safety after he trips the proximity breaker or separates the quick disconnect coupling since no one can re-energize the equipment from a remote location.
  9. Utility Pedestals are provided with Equipment Status indicator-lights which let management know'at a glance the ooerational state of all equipment connected to the Utility Pedestal.
  10. Utility Pedestals adapt simply to numerous electric and electronic controls such as stop-start switches, mechanical and electronic timers, motor controls, water meters, booster water heaters, ground fault circuit interrupters, ground fault sensing and relaying devices, etc.

Specifications:

Provide one Greitzer U.L. listed Power-Pak Utility Pedestal with matching cord and plug sets. Each cord and plug set shall have an individual U.L. listing.

Power-Pak Utility Pedestal shall be fabricated of #16gaugestainless steel of size and shape shown on plans with stainless steel sink, mixing valves, swing faucet, flexible hose with trigger control and soap dish.

Provide one Greitzer model #HPMS motor control and timer package with motor starter and thermal overload, motor reset indicator lights, timer and start and stop buttons.

Utility Pedestal shall be completely pre-wired and pre-plumbed to one connection point and fabricated for easy access to interior components. Each receptacle shall be of standard NEMA configuration and provided with a spring-hinged weatherproof protective cover. Each recebtacle shall be positively grounded to both the face plate and main bodv of the Utilitv Pedestal. Circuit breakers shall be of the all molded casi type with nd external pins. Each circuit breaker shall be provided with a spring-hinged weatherproof protective cover.

Circuit breakers shall have 10,000 ampere interrupting capacity. Each receptacle shall have an engraved gravoply label giving voltage, amperage, phase, item number, and description of equipment connected to the receptacle. Ground fault shall be supplied in accordance with the National Electric Code with all 120voltand240 volt , angle phase receptacles up to and including 30 amperes protected by ground fault circuit interrupters.

Cord and plug assemblies shall be rated to suit equipment being supplied with individual "U.L." labels indicating that it has met the standards of that organization. Cords shall be supplied with galvanized steel strain relief grips on both ends. Cord and plug sets shall be provided with twist lock NEMA configuration plugs.

Upon request of specifier, manufacturer must submit a copy of the U.L. test report and U.L. listing card for the Power-Pak Utility Pedestal and Cord and Plug Sets. Manufacturer shall also make available samples of Cord and Plug Sets, breaker and receptacle combinations, operating samples, drawings, and diagrams of component accessories for evaluation and approval to show manufacturer can meet the standards of the specifier. Information and samples shall be made available for evaluation and approval prior to equipment contractor preparing his submittal.

Shop drawings containing details of construction and information relative to electrical assemblies shall be furnished to the local building department for their approval prior to manufacture.

A representative of Greitzer, Inc. shall be present at the jobsite during the period of installation of the Utility Pedestal equipment to instruct the various trades in the proper installation of their work in relation to the Utility Pedestal unit.

Greitzer, Inc. is not to be responsible for any wiring or plumbing other than that furnished as part of our equipment.

Any equipment which proves defective in a period of twenty-four months after start-up willleitherlbe repaired or replaced at no expense to the owners by Greitzer, Inc. unless such equipment has been damaged by improper installation, alterations by the owner, or improper use of the equipment.